Heating And Cooling Recirculating Air Cooled Water Chiller For Hotel , Office

Product Details
Place of Origin: DongGuan, GuangDong
Brand Name: HIGOLDEN
Certification: CE
Model Number: HLWH-110S ~340S
Payment & Shipping Terms
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Wooden Case
Delivery Time: 10 working days after received your payment
Payment Terms: T/T, Western Union, L/C, MoneyGram
Supply Ability: 500pcs per month

Detail Information

Product Description

 

Heating And Cooling Recirculating Air Cooled Water Chiller For Office / Hotel 

 

 

 

 Model     HLWH~

110S

160S

210S

240S

280S

310S

340S

Rated Cooling Capacity

Cooling Capacity (KW)

109

155

208

245

283

307

337

Comp. Input 

Power (KW)

34.7

47.7

63.2

71.2

82.4

89.9

99.9

Rated Heating 

Capacity

Heating 

Capacity (KW)

119

167

224

260

301

326

360

Comp. 

Input Power (KW)

32.6

44.8 

59.6 

67.0 

77.6

84.6 

94.1 

Refrigerant 

R22

Power Supply 

380V/ 3ph/ 50Hz

Safety Protection

Phase reversion protection, 

Phase lack protection, 

Overload current protection,
Discharge air temp.  protection,

 Low & High pressure protection, 

Low temp.  protection, 

Water flow protection.

Number of Refrigeration Circuit

1

Capacity Control (%)

0, 50, 75, 100

Refrigerant Charge (Kg)

30

42

56

68

78

84

93

Air Cooled Heat Exchanger

 Ripple Aluminum 

Fins Around Copper Pipe


Water Cooled Heat Exchanger

Dia.of Pipe (inch)

2-1/2"

3"

3"

3"

4"

4"

4"

Water Side 

Max Pressure  (MPa)

1

Chilled  Water Flow(m3/h)

18.7

26.7

35.7

42.1

48.7

52.7

58.0

Water Pressure Drop (kPa) 

28

33

48

55

61

64

66

Flow of Hot Water(m3/h)

20.4

28.8

38.4

44.7

51.7

56.1

61.9


Axial Fan

Air Flow×1000m3/h

56.8

80.4

113.6

115.2

115.2

160.8

160.8

Power×Qty (KW)

1.2×4

2.0×4

1.2×8

1.2×8

1.2×8

2.0×8

2.0×8

Running Noise dB(A)

75

75

75

75

75

75

75

Total Weight (Kg)

1550

1960

2940

3120

3300

3480

3660

Running Weight(Kg)

1660

2140

3160

3340

3550

3730

3980

 

 

1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃

   Chilled water inlet/outlet temp. 12℃/7℃,  Fouling factor: 0.088㎡.°C/KW.

2. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃

    Hot water inlet/outlet temp. 40℃/45℃;  Hot water range: 45℃~45℃;

2. Chilled Water Range: 5~20℃;  Lowest Ambient Temperature: -5℃~43℃;

3. Heat recovery unit water in/out temperature: 50℃/55℃;

4.Changes of Specification for lmprovement May Be made without Notice.

 

 

Feature:

 

1. Cooling capacity: 109kw~337kw , Heating capacity:

 

  1. Input power: 3P-380V-50Hz, Allowable fluctuate voltage: ±10%, allowable voltage difference inphase: 
  2. ±2%.
  3. Normal conditions: Chilled water inlet temperature is 12 degrees, outlet temperature is 7 degrees. 
  4. Ambient temperature is -5 degrees to 35 degrees.
  5. 4.Normal conditions: Hot water inlet temperature is 40 degrees,outlet temperature is 45 degrees.
  6. Hot water temperature range is 45 degrees to 50 degrees.
  7. Bitzer, Hanbell, famous brand compressors are available

6.. Accept orders for special requirements

 

7. It can be widely used in hotel, office building, school, hospital, factory and other buildings.

 

8. Easy installation, simple maintenance;

 

9. High precise control and reliable operation.

 

 

Advantage:

 

Compact structure, strong and durable , Compact structure, strong and durable

  1. High efficiency, low noise, low vibration.
  2. Use PLC microcomputer control from Germany SIEMENS LCD touch screen, English human-machine interface.

Heating And Cooling Recirculating Air Cooled Water Chiller For Hotel , Office 0

Want to Know more details about this product
Please enter your inquiry details.
Pultruded FRP Online Market
cschenli@maoyt.com
86-010-87827984-11
Room 501, unit 6, building 20, North Lane, east flower market, Beijing
Leave a Message
*Email
*Message
Send
China Good Quality Temperature Control Units Supplier. Copyright © 2014-2025 closedcoolingtowers.com . All Rights Reserved.